A2_.jpg

Trouble Shooting

Trouble shooting of:

  • Power / efficiency loss
  • Vibration of rotors
  • Turbine controls
  • Control oil system
  • Excitation controls
  • Generator faults

Trouble shooting of:

High radial vibration of the turbine/generator rotor caused by misalignment of the trust journal bearing.
Shaft Ø 350, Trust pad carrier Ø 500, Rotor weight 38 tons

- Solved by modification of bearing body